The A24U 4U-profile RAID system is the only high-density choice on the market with sophisticated RAID protection. With reliable SCSI and clustering support, the A24U-G2421 is a cost-effective, large capacity storage solution to incorporate into disk farms, ATM service centers, and imaging stations that require RAID protection at a lower cost per gigabyte.
- Highlights
- Specifications
- Accessories
- Full-featured RAID functionality with two (2) SCSI-320 host channels; transfer rate up to 320MBps each
- Up to 24TB of storage capacity
- Accommodates twenty-four (24) SATA II hard drives, backward compatible with SATA I drives
- Hardware XOR engine by dedicated ASIC266 chipsets
- Dual-speed cooling modules to reduce system noise
- Backplane-based, cableless, modular enclosure
Host-to-Drive Interface | Model | Configuration | Form Factor |
---|---|---|---|
SCSI-320 to SATA II | A24U-G2421 | Single controller | 4U rackmount |
RAID
- Multiple arrays configurable with dedicated or global hot spare drives
- RAID levels: RAID0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
-
Online expansion by:
- Adding new drives
- Copying and replacing drives with drives of larger capacity
- Automatic background rebuild
- Configurable stripe size and write policy per array
-
Intelligent drive handling:
- In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
System Components
-
Single RAID controller configuration provides full-featured RAID functionality
- One (1) 4U enclosure
- One (1) RAID controller module
- One (1) 512MB DDR RAM DIMM module preinstalled on the controller module; system supports 512MB to 2GB capacity DIMM modules
- Three (3, N+1) hot-swappable, redundant, 405W power supply units
- Twenty-four (24) hot-swappable drive trays
- Two (2) hot-swappable, redundant cooling modules
- Two (2) forearm front handles
- One (1) optional battery backup unit (BBU)
Host Interface
- Two (2) SCSI-320 host channels interfaced through two (2) dual-stacked VHDCIs
- Tagged command queuing up to 256
- Host-side ordered tag support
Drive Interface
- Twenty-four (24) hot-swappable 3Gbps SATA II drive trays that accommodate 1-inch pitch SATA II or SATA I disk drives
- Native Command Queuing (NCQ) support
- Dedicated bandwidth to each connected drive
- Automatic bad sector reassignment
Management
- Firmware-embedded utility via LCD keypad or RS-232C terminal
- 10/100BaseT Ethernet for out-of-band management
- Two (2) COM ports for local access to firmware-embedded utility and UPS connectivity
- Telnet access via onboard Ethernet port
-
Java-based RAIDWatch® Manager
- Graphical user interface
- Local/remote management; in-band or out-of-band via TCP/IP
- Centralized management of multiple subsystems from one management computer
- A variety of event notification methods via the Configuration Client sub-module: email, fax, LAN broadcast, SNMP traps, MSN messenger, ICQ, and SMS short messages
- Secure link over SSL
Indicators
- Onboard alarm
-
Module status LED indicators
- Two (2) per drive tray
- Two (2) per cooling module
- One (1) per power supply unit
- One (1) per BBU module
- Three (3) per LCD panel
- Four (4) per RAID controller module
- Two (2) per Ethernet port
- Module failure indication and temperature/voltage readings through I2C bus
Physical/Electrical
Interfaces
Four (4) 68-pin VHDCIs in dual-stacked configurations Two (2) COM ports for RS-232C terminal and UPS connection (38400, n, 8, 1) One (1) 10/100BaseT Ethernet port
Power Supply Module
Three (3) redundant, hot-swappable power supplies with PFC
Nominal Power | 405W |
---|---|
DC Output |
+3.3V: min. 0.5A, max. 20A +5V: min. 2.5A, max. 36A +12V: min. 1A, max. 24A +5V SB: min. 0A, max. 0.5A |
Input Frequency | 47 to 63Hz |
AC Input | 90VAC @ 8AC , 264VAC @ 4AC with PFC |
Cooling Module
Two (2) redundant, dual-fan cooling modules
Environmental Specifications
Humidity | 5% to 95% (non condensing operating and non-operating) |
---|---|
Temperature |
Operating : 5º to 40ºC Non-operating : - 40º to 60ºC |
Altitude |
Operating : sea level to 12,000 ft Non-operating : sea level to 40,000 ft |
Dimensions
- Chassis without handles: 445W x 174.4H x 498D mm (17.6 x 6.86 x 19.6 inches)
- Chassis with handles 482W x 174.4H x 514D mm (18.97 x 6.86 x 20.2 inches)
- Package: 590W x 480H x 700D mm
System Weight
- Net weight: 36.5kg
- Gross weight: 39.6kg
Spare Parts
IFT-9373CDTray | 3.5" Hard disk drive tray | |
---|---|---|
IFT-9274CPSU | Power supply module, EonStor 4U 24-bay subsystems, 405W (N+1) capacity | |
IFT-9274CFanMod | Cooling fan module for EonStor 4U 24-bay subsystems | |
IFT-9274CHandLLCD | Left-side forearm handle for EonStor 4U 24-bayRAID subsystems, LCD panel included | |
IFT-9274CHandR | Right-side forearm handle for EonStor 4U 24-bay subsystems | |
IFT-84AU24GD24E2 | SCSI to SATA RAID controller module, for ES A24U-G2421-2 subsystem, 4 x SCSI-320 VHDCI host connectors, RAID 6. | |
IFT-DDRESCEM5 | 512MB DDR RAM DIMM module, for ASIC266 platform | |
IFT-9270ASCab | RS-232C serial cable, audio-jack to DB9 | |
IFT-9011 | Null Modem, DB9 female to DB9 male, wires swapped |
Accessories
IFT-9272CDTrayDmy | Dummy Drive tray, Type-II bezel | |
---|---|---|
IFT-9274CBTC | Battery cell pack, Li-Ion, EonStor 4U 24-bay subsystems | |
IFT-9270UHstCab | SCSI external round cable, DB68 to VHDCI | |
IFT-9270UJBODCab | SCSI external round cable, VHDCI to VHDCI | |
IFT-9270CUPSCab | UPS cable, audio-jack to DB9 | |
IFT-9373CSLIDER36 | Slide rail assembly, for all EonStor G6 and EonStor DS subsystems, 24"~36" rack depth | |
IFT-DDRESCEMA | 1GB DDR RAM DIMM module, for ASIC266 platform |